Biolight S10 Patient Monitor
Thai FDA Advertising License: ฆพ.269/2568
Advertisement No.: 67-2-2-2-0011284
The Biolight S10 Patient Monitor is designed for use in hospitals, clinics, emergency departments, ICUs, and recovery rooms. Built upon over 27 years of Biolight's expertise in developing advanced patient monitoring solutions, the S Series combines ergonomic design, next-generation software architecture, and innovative monitoring technology to enhance clinical workflow and patient care.
Key Features
- 10.4-inch TFT Color LCD Touch Screen with 800 × 600 resolution
- Monitors ECG, HR, RESP, NIBP, SpO₂, and Temperature
- Ergonomic design with an integrated hidden handle for easy portability
- High-resolution capacitive touchscreen
- Supports Gesture Control
- Automatic screen brightness adjustment
- Seamless front panel for easy cleaning and infection control
- Rechargeable Lithium-ion battery with up to 4 hours of continuous operation
- Supports Wi-Fi, Cloud connectivity, and hospital networking
- Multi-level visual and audible alarm system
- 1-Year Warranty
General Specifications
- Dimensions: 168 × 288 × 236 mm
- Weight: Less than 4 kg
- Power Supply: 100–240V AC, 50–60Hz
- Battery: Rechargeable Lithium-ion 11.1V / 2.5Ah
- Battery Operating Time: Up to 240 minutes
- Display: 10.4-inch TFT Color LCD Touch Screen
- Customizable parameter display layouts
Technical Specifications
- ECG
Standard 3-Lead (I, II, III)
Optional 5, 6, and 12-Lead ECG
Multiple gain selections
CMRR ≥110 dB (Monitor Mode)
Bandwidth: 0.5–40 Hz
Defibrillation recovery time: 10 seconds
- ST Segment Analysis
Measurement Range: -2.0 to 2.0 mV
Accuracy: ±0.02 mV
- Heart Rate (HR)
Adult: 10–300 bpm
Pediatric & Neonatal: 10–350 bpm
Accuracy: ±1%
- Arrhythmia Analysis
Detects and analyzes 27 types of cardiac arrhythmias
- Respiration (RESP)
Measurement Range: 0–150 breaths/min
Accuracy: ±2 rpm
- BLT Digital SpO₂
Measurement Range: 0–100%
Accuracy: ±3% (70–100%)
- Pulse Rate (PR)
Measurement Range: 25–300 bpm
Accuracy: ±3 bpm
- Temperature
Supports T, T2, and TD parameters
Measurement Range: 0.0–50.0°C (32–122°F)
Selectable °C / °F
Resolution: 0.1°C
Accuracy: ±0.1°C
- Non-Invasive Blood Pressure (NIBP)
Automatic Oscillometric Measurement Technology
Measurement Modes: Manual, Auto, and STAT
Supports Adult, Pediatric, and Neonatal patients
Static Accuracy: ±3 mmHg
Clinical Accuracy: Mean error ±5 mmHg
Measurement Time: 20–45 seconds
Built-in overpressure protection for enhanced patient safety
Alarm System
- On-screen alarm messages
- Three-level visual alarm indicators:
Red: High Priority
Orange: Medium Priority
Blue: Low Priority
- Adjustable audible alarm with up to 10 volume levels
Memory Capacity
- Alarm Events: Over 3,000
- Trend Data: More than 180 hours
- Arrhythmia Events: Over 3,000
- NIBP Records: Over 2,400
- Holographic Waveform Storage: More than 72 hours
Connectivity
Supports connection to external devices and hospital systems, including:
- USB Keyboard
- USB Mouse
- USB Barcode Scanner
- RJ45 Ethernet Network
- Dual USB Ports
- Nurse Call Interface
- Defibrillator Synchronization
- Analog Output
- Wi-Fi Connectivity
- Cloud / IoT Integration
Standard Accessories
- Biolight S10 Patient Monitor ×1
- 3-Lead ECG Cable ×1
- SpO₂ Sensor ×1
- Temperature Probe ×1
- NIBP Hose ×1
- Blood Pressure Cuff ×1
- AC Power Cord ×1
- User Manual ×1
Warranty & Service
- 1-Year Warranty
- Nationwide free shipping
- Local service center with professional technical support and after-sales service.