Biolight V9 Vital Signs Monitor (1-Year Warranty)

Attribute:

The Biolight V9 Vital Signs Monitor is a professional patient monitoring system designed to continuously measure and display essential vital signs, including SpO₂ (oxygen saturation), pulse rate (PR), non-invasive blood pressure (NIBP), respiratory rate (RR), and body temperature. Featuring an 8-inch TFT color touchscreen, up to 10 hours of battery life, and comprehensive alarm functions, it is ideal for hospitals, clinics, emergency departments, and outpatient care.

Share

Biolight V9 Vital Signs Monitor

Thai FDA Advertising License: ฆพ.1264/2568
Advertisement No.: 68-2-2-2-0005061

Intended Use

Designed for continuous monitoring of patient vital signs, including:
   Blood Oxygen Saturation (SpO₂)
   Pulse Rate (PR)
   Respiratory Rate (RR)
   Non-Invasive Blood Pressure (NIBP)
   Body Temperature

General Specifications

  • Dimensions (W × D × H): 308 × 233 × 125 mm
  • Weight: ≤ 4 kg
  • Power Supply: AC 100–240 V, 50/60 Hz
  • Input Current: 1.5–0.7 A
  • Battery: Rechargeable Lithium-ion, 10.8 V / 6.6 Ah
  • Battery Runtime: Up to 10 hours
  • Display: 8-inch TFT Color LCD Touchscreen
  • Resolution: 800 × 600 pixels

Key Features

  • Measures SpO₂, Pulse Rate, Respiratory Rate, NIBP, and Body Temperature
  • Large 8-inch high-resolution touchscreen for intuitive operation
  • Adjustable display layouts with color-coded parameters for easy viewing
  • 12° tilted display provides improved viewing angle and user comfort
  • Physiological alarm system with visual and audible alerts (High, Medium, and Low priority)
  • Long-lasting rechargeable battery for portable monitoring
  • Suitable for hospitals, clinics, emergency departments, and bedside monitoring

Technical Specifications

SpO₂ Monitoring
Measurement Range: 0–100%
Accuracy: ±2% (70–100%)

Pulse Rate (PR)
Measurement Range: 20–250 bpm
Accuracy: ±1 bpm or ±1%

Body Temperature
   Compatible with Covidien Filac 3000 Smart Electronic Thermometer
   Temperature Range: 30.0–43.0°C
   Measurement Sites:
          - Oral
          - Axillary
          - Rectal
   Measurement Modes:
          - Quick Mode
          - Cold Mode
          - Monitor Mode
   Units: °C / °F
   Resolution: 0.1°C (0.1°F)
   Accuracy: ±0.1°C

Non-Invasive Blood Pressure (NIBP)
   Oscillometric measurement technology
   Measurement Modes:
          - Manual
          - Auto
          - STAT
   Automatic Interval:
          - Every 1, 2, 3, 4, 5, 10, 15, 30, 60, or 90 minutes
          - Every 2, 4, or 8 hours

Blood Pressure Measurement Range
Adults
   Systolic: 30–270 mmHg
   Diastolic: 10–220 mmHg
   Mean Pressure: 20–235 mmHg

Pediatric
   Systolic: 30–235 mmHg
   Diastolic: 10–220 mmHg
   Mean Pressure: 20–225 mmHg

Neonatal
   Systolic: 30–135 mmHg
   Diastolic: 10–100 mmHg
   Mean Pressure: 20–125 mmHg

Additional NIBP Features:
   Cuff Pressure Range: 0–300 mmHg
   Pulse Rate Range: 40–240 bpm
   Static Pressure Accuracy: ±3 mmHg
   Clinical Accuracy:
          - Mean Error: ±5 mmHg
          - Standard Deviation: < ±8 mmHg
   Built-in software over-pressure protection:
          - Adult: 297 ±3 mmHg
          - Pediatric: 252 ±3 mmHg
          - Neonatal: 147 ±3 mmHg

Alarm System
   Physiological alarm with audible and visual notifications
   Three priority levels:
          - High
          - Medium
          - Low

Memory Capacity
   Patient Records: More than 1,000
   Parameter Records: More than 5,000
   Alarm Events: More than 100,000
   Log Events: More than 10,000

Connectivity
   USB Keyboard & Mouse Support
   USB Barcode Scanner
   RJ45 Wired Ethernet
   Hospital Network Support (RJ11 / EMR / HL7)
   Dual USB Ports

Warranty & Service

  • 1-Year Warranty
  • Nationwide free shipping
  • Local service center with professional technical support and after-sales service.